康普特电子科技有限公司

contact us

Tel:  +86-596-2106072   +86-596-2109072

E-mail: sales@kangput.com   

              kpt01@kangput.com

              kpt02@kangput.com

Skype: kvnput& kangput  &   kangput2

Add: Lantian Industrial Zone, Longwen District, Zhangzhou City,Fujian Province,China

                   

HDS-N Series Handheld Digital Storage Oscilloscope

2 in 1 (DSO + Multimeter)

Auto-scale function

FFT function

20 group automatic measurement options

Bandwidth : 20MHz - 100MHz

USB data transmission supported

Rechargeable Li-ion battery (6 hours' backup)

Waveform record andreplay  (equipped in HDS2062M-N, HDS3102M-N)

Multimeter newly supported SCPI

More detailsInquiry


Applications:  

    electronic circuit debugging        circuit testing       design and manufacture

    education and training                    automobile maintenance and testing

Performance Specifications

Model

HDS1022M-N

HDS2062M-N

HDS3102M-N

 Bandwidth

 20MHz

 60MHz

 100MHz

 Sample Rate (real time )

 100MS/s

 500MS/s

 1GS/s

 Horizontal Scale (s/div)

 5ns/div~100s/div, step by 1~2.5~5

 5ns/div~100s/div, step by 1~2~5

 Rise Time (at input, typical)

 ≤ 17.5ns

 ≤ 5.8ns

 ≤ 3.5ns

 Display

 3.7 inch color display with TFT panel (640 × 480 pixels, 65535 colors)

 Channel

 dual

 Input Impedance

 1MΩ ± 2%, in parallel with 20pF ± 5pF

 1MΩ ± 2%, in parallel with 15pF ± 5pF

 Record Length

 max 6K points on each channel

 Interpolation

 sin (x) / x

 Probe Attenuation Factor

 1X,10X,100X,1000X

 Input Coupling

 DC, AC, and GND

 DC Accuracy (average)

 average >16 : ±(5% reading + 0.05div) for △V

 Vertical Sensitivity

 5mV/div~5V/div (at input)

 Vertical Resolution (A/D)

 8 bits (2 channels simultaneously )

 Max Input Voltage

 400V (PK - PK) (DC + AC, PK - PK, 1MΩ input impedance, probe attenuation 10 : 1), CAT II

 Trigger Type

 Edge, Video, Alternate

 Trigger Mode

 Auto, Normal, Single

 Trigger Level

 ±6 divisions from screen center

 Acquisition Mode

 Sample, Peak Detect, and Average

 DC Gain Accuracy

 ±3%

 Waveform Math

 +, -, ×, ÷, invert, FFT

 Waveform Storage

 4 waveforms

Lissajous

 Figure

Bandwidth

 full bandwidth

Phase Difference

 ±3 degrees

 Communication Interface

 USB

 Power Supply

 100V-240V AC, 50/60Hz

 Li-ion Battery

 7.4V, 6 hours operation

 Dimensions (W × H × D)

 180 × 115 × 40 (mm)

 Weight (without package)

 645 g

Multimeter Specifications 

Full Scale Reading

3 .3/4digits(max4000 count)

Diode

0V-1.5V

Input Impedance

10MΩ

On/Off Test

<50(+-30)beeping

Voltage 

VDC : 400mV, 4V, 40V, 400V, 1000V : ±(1% ± 1 digit); max input : DC 1000V

VAC : 4V, 40V, 400V : ±(1% ± 3 digits), 750V : ±(2% ± 3 digits); Frequency : 40Hz - 400Hz;

max input : AC 400V (virtual value) 

Current 

DC : 40mA, 400mA : ±(1.5% ± 1 digit), 20A : ±(3% ± 3 digits)

AC : 40mA : ±(1.5% ± 3 digits), 400mA : ±(2% ± 1 digit), 20A : ±(5% ± 3 digits) 

Impedance 

400Ω : ±(1% ± 3 digits), 40ΚΩ - 4ΜΩ : ±(1% ± 1 digit), 40MΩ : ±(1.5% ± 3 digits) 

Capacitance 

51.2nF~100uF : ±(3% ± 3 digit) 

Accessories

 Probe

Probe Adjust

USB

Power Cord

CD Rom

Multimeter Lead

 

Adapter

5V, 1KHz Output

 Capacitance Ext Module

  Metal Case

Soft Bag (optional)